Maintenance of cooling and freezing equipment

AD ID: 11382058 • ភ្នំពេញ • 6d

តម្លៃចចារ

Main Category :
Services
Category :
Other Services

The following maintenance checklist can help companies prolong the useful life of their refrigeration equipment. Condensers Clean them regularly, especially air-cooled types The frequency of cleaning depends on the condenser location and its surrounding environment Check fan/pump motors all work Check fans are not loose on motors Compressors Carry out standard maintenance if required Recover oil and recharge compressors as necessary (ammonia systems) Air coolers Clean them regularly Check the defrost (where necessary) is working correctly Check the defrost control allows the optimum time for defrosting Check fan/pump motors all work Check fans are not loose on motors Liquid chillers - Check water pump operation. Liquid line filter drier - Check for blockage and replace if necessary. Refrigerant charge Check liquid level in the receiver or check for bubbling in the liquid line sight glass Check for leaks all-round the system and repair (this is required under EU 'F-gas' regulations on the use of fluorinated greenhouse gases) Control Ensure the discharge pressure is as low as possible; in particular, check that head pressure control settings are not too high Check that the suction pressure is as high as possible Check cold room/process temperature set points; they should not be lower than required Check superheat setting of expansion valves and adjust if necessary Insulation Replace suction line insulation if necessary Replace chilled liquid line insulation if necessary Repair or replace cold store insulation if necessary Cold store doors Ensure doors are not left open unnecessarily Repair or replace door seals if necessary Repair or replace strip curtains if necessary Repair or replace air curtain if necessary Ice build-up If condensate pipes are iced-up, applying gentle heat will help to defrost Integral defrosting elements should work correctly Ice build-up on evaporators indicates to poor heat exchange Light ice build-up can be removed with a brush, but heavy ice has to be removed as described in manufacturer guidelines In order to avoid damage, sharp objects should never be used for de-icing The Retail Code of Conduct includes information on service and maintenance of cooling systems

ព័ត៌មានទំនាក់ទំនង: សូមកុំភ្លេចនិយាយថាអ្នកបានឃើញការផ្សព្វផ្សាយនេះនៅលើ ខ្មែរ២៤។

ទីតាំង: Borey vimean Phnom Penh. Bak Khaeng, Chrouy Changva, Phnom Penh

រក្សាទុក
រាយការណ៌
ចែករំលែក
ការមិនទទួលខុសត្រូវ / Disclaimer
យើងខ្ញុំមិនគ្រប់គ្រងមាតិកា ដែលបានបង្ហោះឡើងដោយសមាជិកឡើយ។ ដូច្នេះយើងមិនទទួលខុសត្រូវលើការផ្សាយផលិតផលនេះទេ ហើយក៏មិនធានាចំពោះបញ្ហាដែលទាក់ទងដោយផ្ទាល់ ឬ ប្រយោលទៅនឹងសកម្មភាព ឬ អសកម្មណាមួយឡើយ។
We does not control the content posted by members and therefore assumes no responsibility and disclaims any liability for any consequence relating directly or indirectly to any action or inaction.

មតិ  

Venghang Heng

Venghang Heng

@HSP_2024

សមាជិកតាំងពី 2019-12-02 09:31:12

ភ្នំពេញ , Borey vimean Phnom Penh.

warning ព័ត៌មានសុវត្ថិភាពសម្រាប់អ្នកទិញ
Safety Tips for Buyers

1.

មិនត្រូវធ្វើការផ្ញើប្រាក់ទៅមុន មុនពេលទទួលទំនិញ
Do note sent money before receiving the goods

2.

សូមពិនិត្យមើលទំនិញមុនពេលដែលអ្នកទិញ
Check the item before you buy

3.

បង់ប្រាក់បន្ទាប់ពីទទួលបានទំនិញ
Payment ofter receiving the goods

4.

ត្រូវជួបអ្នកលក់នៅទីតាំងដែលមានសុវត្ថិភាព
Meet the seller at a safe location

ការប្រកាសដែលទាក់ទងគ្នា

របាយការណ៌ទទួលបានជោគជ័យ!